加入收藏 在线留言 联系我们
关注微信
手机扫一扫 立刻联系商家
全国服务热线13641974701
公司新闻
安科瑞多回路仪表在德国数据中心的应用
发布时间: 2024-02-18 14:42 更新时间: 2024-12-22 10:00

Application of Acrel multi - loop meter in German data center


摘要:数据中心是一个聚集了大量服务器、存储设备、网络设备及配套UPS、空调等设备的IT设备场所,是实现数据信息的集中处理、存储、传输、交换和集中管理等业务的服务平台。


数据中心供电电源质量的好坏直接影响到IT设备的安全运行,因此对数据中心列头柜电源进出线实行监测非常重要,另外,随着全球可用能源的减少以及能源成本的提高,如何更加经济和使用能源已成为相关企业责无旁贷的责任。


Abstract: Data center is a place that gathering a large number of servers, storage equipment, network equipment and supporting UPS, precision air conditioning and other IT equipment, is to realize the centralized processing, storage, transmission, exchange and centralized management of data and information service platform.


Data center power supply quality directly affects the safe operation of the IT equipment, thus the data center column header tank outlet and inlet line of power supply monitoring is very important, in addition, as the global of available energy and reduced energy costs rise, how much more economic and efficient use of energy has become a duty-bound responsibility related enterprises.


1.项目概述 Project overview


针对数据中心列头柜对于监测装置的要求,我司设计了AMC16-FAK48数据中心监控装置来实现多路出线的电参数及进出线开关状态等实现监测。innovIT AG是德国的数据中心制造商之一,这款多达48单相交流出线回路监测的仪表, 搭配安科瑞的开口式互感器AKH-0.66-K-φ10一起使用,满足了客户监测39个単相回路监测的要求。


According to the requirements of data center array cabinet for monitoring device, our company designed AMC16-FAK48 data center monitoring device to realize the electrical parameters of multiple outgoing lines and the switch state of incoming and outgoing lines to achieve comprehensive monitoring. InnovIT AG is the largest data center manufacturer in Germany. This meter, which can monitor up to 48 single-phase AC outlet circuits, is used together with Acrel’s split core CT AKH-0.66-K-Φ10 to meet customers' requirements for monitoring 39  circuits.


2. 功能 Function

967221089.jpg

2.技术参数Technical Features

969296696.jpg

3.组网拓扑图 Network topology

971149920.jpg

4.现场图片Photo on-site

975621581.jpg

5.结束语Conclusion


随着数据中心的迅猛发展,数据中心的能耗问题也越来越突出,有关数据中心的能源管理和供配电设计已经成为热门问题,可靠的数据中心配电系统方案,是提高数据中心电能使用效率,降低设备能耗的方式。要实现数据中心的节能,首先需要对每个用电负载实现监测,而数据中心负载回路非常的多,传统的测量仪表无法满足成本、体积、安装、施工等多方面的要求,因此需要采用适用于数据中心集中监控要求的多回路监控装置。


而AMC16M是专门针对数据中心交流列头柜开发设计的,对此类产品的应用做了深入的研究,从功能、性能、可用性、经济性等方面都优于其他方案。


With the rapid development of data centers, the problem of energy consumption in data centers is becoming more and more prominent. Energy management and power supply and distribution design of data centers have become hot issues. Efficient and reliable data center power distribution system scheme is an effective way to improve the power use efficiency of data centers and reduce the energy consumption of equipment.To realize the energy saving of the data center, you will first need to achieve precise monitoring of each power load, the load circuit and data center very much, the traditional measuring meters can meet the cost, size, installation, construction and other aspects of requirements, so you need to use applies to data center centralized monitoring requirement of multi loop monitoring device.


The AMC16M is specially designed for array cabinet in data center. The application of this kind of product has been studied in depth, and it is superior to other schemes in terms of function, performance, availability and economy.


参考文献 Bibliography


Solutions for enterprise micro-grid system 


联系方式

  • 电  话:021-69152639
  • 经理:张经理
  • 手  机:13641974701
  • 传  真:021-69153629
  • 微  信:13641974701